What size gas line do I need for a 4 burner gas hob?

Hey, let’s cut to the chase: if you’re here Googling “what size gas line do I need for a 4 burner gas hob,” you’re probably not a textbook engineer—you’re a restaurant owner replacing a busted hob line, a handy homeowner finally tackling their outdoor kitchen, or maybe even a contractor who’s messed up a gas line sizing before and doesn’t want the 2 a.m. call from a plumber at 3 a.m. when something’s wrong. And since I’ve been supplying 4 burner gas hobs for over 7 years now, I’ve answered this exact question so many times I could recite it over a post-shift coffee. No jargon, no confusing formulas, just the real stuff you need to get right the first time. 4 Burner Gas Hob

First, let’s get one thing straight: this isn’t a one-size-fits-all answer. A lot of new supply guys will try to throw a 1/2 inch line at you and call it good, but that’s only half the story (pun absolutely intended). The right size depends on three big things: what type of gas you’re using, how far the line has to run from your main gas meter/valve to your hob, and even how old your building’s gas system is. I’ve seen a tiny, 10-year-old meter blow a fuse when someone hooked a commercial 4 burner hob to it, and a new line in a 50-year-old home get clogged with rust because the wrong sized line didn’t carry enough pressure.

Let’s start with the basics most people skip: fuel type. There are two main ones for gas hobs here in the US (and I’m assuming you’re in the US if you’re looking for standard sizing, but this applies to most places with natural gas and propane): natural gas (NG) and liquid propane (LP, or sometimes just “propane”). Natural gas is piped into most homes and restaurants, runs at lower pressure—usually around ½ psi, give or take. Propane, if you’re using a tank (like for outdoor kitchens or mobile food trucks), runs at a way higher pressure, like 11 psi. That difference alone changes everything.

Now, your 4 burner gas hob—let’s take the standard models I supply. Every 4 burner has a BTU rating on it; that’s the total amount of heat it puts out when all four burners are cranked all the way. For residential 4 burner hobs, that’s usually between 35,000 BTU and 45,000 BTU total. Commercial ones? Way higher—up to 60,000 BTU, sometimes more for heavy-duty restaurant use. That number is non-negotiable. If you get a line that can’t carry enough BTU, your burners will be weak, your food will take forever to cook, and you might even have safety issues.

Okay, so let’s break down the sizing step by step, no math that makes your eyes glaze over. We use a standard chart in the industry, but I’ll make it simple. This is for copper lines, which are the most common for gas hobs (PVC? Forget it—never use plastic for gas lines, that’s a safety red flag).

First, natural gas:
If your line is 20 feet or less from the main gas source to the hob: 1/2 inch inner diameter (ID) line works for almost all residential 4 burner hobs (up to 45,000 BTU). That’s what I recommend for most home installs.
If your line is between 20 and 50 feet: still 1/2 inch ID, but double-check your meter. Make sure your meter can push at least 50,000 BTU (most residential meters are rated for that, but old ones from the 90s or earlier might only do 40,000—so upgrade the meter first if that’s you).
If your line is over 50 feet: bump up to 3/4 inch ID. Don’t skip this—gas loses pressure the farther it travels, so a 1/2 inch line stretched 60 feet won’t carry enough BTU for your burners, even if your hob is only 40,000 BTU. I’ve seen this go wrong more times than I can count: a guy in Ohio tried to save a few bucks on line size for his 250 sq ft outdoor kitchen, ran a 1/2 inch line 70 feet, and his back burners were so weak he couldn’t boil water for pasta. Total waste of time.

Now, propane—this is where most people mess up, because propane is denser and needs a bigger line. For propane, the BTU rules are a little different, but the core idea is pressure drop. If you’re using propane tanked on your property:

  • For a residential 4 burner (35-45,000 BTU) with a line under 20 feet: you need 3/8 inch ID line. Wait, that’s smaller than natural gas? Yep, because propane is higher pressure.
  • If the line is 20 to 50 feet for propane: still 3/8? No, wait—wait, 3/8 only works up to 10 feet for propane over 50,000 BTU, so a 40,000 BTU hob at 30 feet is okay, but if you’re running 30 feet, go 1/2 inch ID. For lines over 50 feet for propane, 3/4 inch ID, no exceptions.
  • And pro tip: never run a propane line longer than 100 feet. If your hob is that far from your tank, you’ll need a booster pump anyway, so don’t even mess with line sizing past that—just call a tech.

Wait, but hold on—what if you’re a restaurant with a commercial 4 burner hob that’s 50,000 to 60,000 BTU? Let’s adjust that. For natural gas commercial: 20 feet or less = 3/4 inch ID, 20-50 feet = still 3/4, over 50 = 1 inch. For propane commercial 4 burners: even bigger—20 feet or less = 1/2 inch, 20-50 = 3/4, over 50 = 1 inch. That makes sense, because commercial hobs run more BTU to keep up with high-volume cooking.

Now, let’s talk about the mistakes I see every day, because these are the ones that get people in trouble. First: ignoring pressure drop. A lot of people look at the total BTU of their hob and just grab a line that matches that BTU, not factoring in distance. I had a client last year who installed a 40,000 BTU residential hob, ran a 1/2 inch line that was 65 feet long, and the burners only put out 28,000 BTU—half what they should. He had to rip out the old line and pay twice as much to put in a 3/4 inch. That’s avoidable, just measure the distance first.

Second: using the wrong line material. Never use black iron? No, wait—black iron is actually common for commercial runs, but copper is fine for residential. Just don’t use any plastic pipe, period. The only plastic allowed for gas lines is very specific PEX for indoor, but I still don’t recommend it for hobs. It can crack over time, and if you have a leak, you won’t see it. I’ve had a couple of leaks from plastic lines over the years, so trust me on this—stick to copper or black iron.

Third: mixing up natural gas and propane sizing. Like I said earlier, propane needs smaller lines than natural gas for short distances, but longer distances need bigger. A guy came to me last month who hooked a propane 4 burner to a natural gas line (don’t do that either—they’re different orifices) and used a 1/2 inch line, and it ran so rich it was blowing yellow flames. He had to swap the orifices and the line size. That’s a double headache.

Another thing: if you’re installing a new line, always check your gas meter rating. The meter has a BTU output on it—if your hob’s total BTU is higher than the meter can handle, your burners will be weak, or the meter will trip. For example, a typical residential natural gas meter is rated for 100,000 BTU, so even a 60,000 BTU commercial 4 burner will be fine, but if you have a super old meter from before 1980, it might only do 50,000 BTU, so you’ll need to upgrade the meter first. That’s not a hob problem, that’s a line/meter problem.

Wait, what about venting? No, wait, no—gas line size is separate from venting, don’t mix those up. Venting is for the exhaust, but line size is for the gas supply. That’s a different question.

Let’s also talk about real-life examples, because numbers are boring. Let’s say you’re a homeowner, installing a new 4 burner residential natural gas hob, your gas meter is on the side of your house, and your kitchen is 15 feet from the meter. You need 1/2 inch ID copper line. That’s it. If you’re a food truck owner, you have a 4 burner propane hob, your propane tank is parked 12 feet from the truck, line is under 20 feet: 3/8 inch line. If you’re a small café, 4 burner commercial natural gas hob, kitchen is 40 feet from the main gas line: 3/4 inch copper line. That’s exactly the kind of installs I help customers with every week.

Now, the safety note—because this is not a time to guess. If you’re not comfortable measuring line sizing, don’t mess around. Call a licensed gas fitter. I always tell my customers: I can supply you the perfect 4 burner hob, but if your line is wrong, that hob’s not going to work right, and safety is on you. I’ve had a few customers try to do it themselves, miscalculate, and have a leak—thankfully no accidents, but that’s a risk no one needs to take.

But if you’re good with measurements, here’s the quick cheat sheet I keep taped to my desk for all my team:

  • Residential 4 burner (35-45k BTU):
    NG: <20ft = 1/2”, 20-50ft = 1/2”, >50ft = 3/4”
    LP: <10ft = 3/8”, 10-50ft = 1/2”, >50ft = 3/4”
  • Commercial 4 burner (50-60k BTU):
    NG: <20ft = 3/4”, 20-50ft = 3/4”, >50ft = 1”
    LP: <20ft = 1/2”, 20-50ft = 3/4”, >50ft = 1”

That’s it. No extra math, no fancy charts. That’s what we use every day for our 4 burner gas hobs, and it’s never let us down.

Now, let’s circle back to why this matters for you, since you’re probably looking to buy a 4 burner gas hob soon. When you order from us, we’ll send you a free sizing guide tailored to your model—no generic stuff, just what you need for the exact hob you’re getting. And if you have questions, our team of techs doesn’t just sell hobs—we’ve installed hundreds, so we know the line sizing, the meters, the pressure drops, all of it. We don’t do the “just use 1/2 inch” line that a lot of suppliers push; we tell you the truth, even if it means you might need a slightly bigger line.

Wait, one last thing to add: if you’re running a line through walls or underground, make sure you’re using the right rated line. Underground copper needs to be type L or K, not type M, which is for indoor use. That’s another common mistake—someone runs type M copper underground, it corrodes in 5 years. Again, we can help you with that when you reach out.

So, to wrap this up: don’t just pick a line size based on your hob’s BTU. Factor in your gas type, the distance from your supply, and your meter rating. Stick to copper or black iron, no plastic. If you’re unsure, get a pro to check, or hit us up. If you’re ready to buy a 4 burner gas hob, we have all sizes, from residential to commercial, all tested for safety and performance, and we can walk you through every step of the setup, including line sizing.

100L Disinfection Cabinet Want to make sure you get the right hob and line size for your space? Get in touch with us to discuss your needs—we’ll help you pick the perfect 4 burner gas hob and confirm the exact line size you need, no guesswork, no hidden fees. We’re here to make sure your install goes smooth, so you can get back to cooking, whether that’s for your family or your restaurant.


  1. National Fuel Gas Code (NFPA 54) – Standard for gas piping sizing and safety, 2023 Edition
  2. Propane Gas Supply Association (PG) – Residential and commercial gas line sizing guidelines for propane, 2022
  3. Copper Development Association (CDA) – Gas piping specifications for copper tubing, 2021
  4. International Fuel Gas Code (IFGC) – Commercial gas line sizing requirements for food service equipment, 2023
  5. HVAC & Refrigeration Institute (AHRI) – BTU rating standards for 4 burner gas hobs, 2022

Hangzhou DE&E Smart Home Co., Ltd.
As one of the most experienced 4 burner gas hob manufacturers and suppliers in China, we offer a wide range of products with superior quality. Please feel free to wholesale cheap 4 burner gas hob from our factory. Contact us for more details.
Address: No.98 Hongxing Road, Xiaoshan District, Hangzhou City, Zhejiang Province 311231, China
E-mail: sabrina.liao@chinadee.com
WebSite: https://www.deeappliances.com/